Telephone Line Connections
There are two methods of connection for the TSD402 to the telephone line. The first is to
use the 2 metre lead supplied (recommended method of connection) which will directly
plug into any standard British Telecom telephone socket. The second is to directly connect
the unit to an NTE5 Master Socket (Line Box). Figure 5 shows both methods of connection.
TRIGGER
A
P
F
+
-
AUX 12V
+-
TRIG POLARITY
12Von alarm
N.O.
Loop
N.C.
Loop
1KW
resistor
TSD402
Alarminput = NormallyClosed
PAinput = NormallyOpen
Fireinput =Switched+ve
TRIGGER
A
P
F
+
-
AUX 12V
+-
TRIG POLARITY
0Von alarm
N.C.
Loop
N.O.
Loop
1KW
resistor
TSD402
Alarminput = NormallyOpen
PAinput = NormallyClosed
Fireinput =Switched-ve
Figure 4 Signalling Types for Auxiliary Dialler Inputs
A
B
BC
A
B
BC
White
Red
Blue
Standard BT telephoneplug
TSD402
TSD402
Connectionusing the lead supplied
Directmethod of connection
3
2
1
6
5
4
Orange/Whitering
White/Bluering
Blue/Whitering
BTMaster Jack (NTE5)
Useraccessible connections
Cabletype 1/0.5mmCW1308
Figure 5 The Two Methods of BT Line Connections
TSD402 Installation Manual System Installation
17