18. View Circuits
This option allows the user to view the stat us of each detection
circuit. The circuit status conditions are H=Healthy, A=Active,
S=Shorted or T=Tamper.
1. Ensure that "User Menu 2" is selected.
2. Press 1 to select the View Circuits option.
3. Circuit status will be displayed.
4. Select circuits either b y entering the number or by pressing
[ to scroll through the circuits.
5. Press ] to leave this option and return to ‘User Menu 2’.
19. Change Time
The systemclockmaybe changedusing24hourclockformat.
1. Ensure that "User Menu 2" is selected.
2. Press 2 to select the Change Time option.
3. Enter the time in 24 ho ur notation (e.g., 1805).
4. Press [ to accept.
20. Change Date
The system c alen dar may be changed by entering the date as
four digits r epresent ing t he day and month e.g., 0207 is the 2nd
July.
1. Ensure that "User Menu 2" is selected.
2. Press 3 to select the Change Date option.
3. Enter the dat e as four digits .
4. Press [ to accept.
21. Setup New Users
Up to 12 users can be allocated to operate the alarm system.
The master user (user 1) can change all user passcodes. If a
passcode is entered with the first two digits reversed, a "Duress
Alarm" is gene rated. If this faci lity is not required ensure that the
1st and 2nd digits are the same, (e.g., 1123). If a passcode is
entered with the last two digits reversed, the "Access Control"
outputis op erated.Ifthisfacilityisnotrequired ensurethatthe3rd
and 4th digits are the same, (e.g., 1233).
1. Ensure that "User Menu 2" is selected.
2. Press 4 to select the Setup New Users option.
3. Enter the user number (1 to 9 or A,B,C).
4. Enter the new passcode the n p ress [ to accept.
8
TS700 LED User Operating Instructions
----
Waiting for date entry.
0207
Date entered (02 July)
Ur -
Waiting for passcode type [1] -
[9] or [A] or [B] or [C].
----
Waiting for time entry.
1805
Time e ntered 1805 (6:05 pm )
03-H
Circuit 03 is Healthy
03-A
Circuit 03 is Active.