Menvier Security TS700 Specifications Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
Commercial Part-Set Application
This application example shows how to use the
"Code Set Groups" to set and unset different areas
within a commercial premises. Using the drawing
of the building the following is required:
The Sales Manager requires independent
access to the Sales department and the
Canteen.
The Workshop Manager requires independent
access to the Workshop area and the
Canteen.
The Stores Manager requires independent
access to the Stores area and the Canteen.
The Service Manager requires independent
access to the Service department.
1. From the above requirements assign each
area to a ward, e.g.:
Ward A: Sales department and Canteen.
Ward B: Workshop and Canteen.
Ward C: Stores and Canteen.
System Ward: Service department.
2. Using the above ward requirements create a
Table for assigning circuits to wards. Circuits
withnoticksareassignedto the“SystemWard”:
Circuit Location Ward A Ward B Ward C
01 Sales Entrance Door 4
02 Sales PIR 4
03 Workshop PIR (1) 4
04 Workshop Entrance 4
05 Workshop PIR (2) 4
06 Workshop door 4
07 Workshop PIR (3) 4
08 Sales Internal Door 4
09 Canteen Door 4 4 4
10 Canteen PIR 4 4 4
11 Stores Entrance 4
12 Stores PIR 4
13 Stores Internal Door 4
14 Sales (Office PIR) 4
15 Service Entrance
16 Service PIR
+
The canteen door and PIR are assigned
to wards A, B and C, this will ensure that
they are only armed when all three
wards are set. This allows access to the
canteen when any of the wards A, B or C
are unset.
3. From the Table assign circuits 01-16 to their
relevant wards (see Configure Wards” on
page 37).
4. Program the code set groups (see “Code set
Groups”, on page 43).This ensures that when
theuserenterstheirpasscode thecorrectward
set or unsets. For this application example the
code set groups are programmed as follows:
Full Set Group: [S ]
Code Set Group A: [ A ]
Code Set Group B: [ B ]
Code Set Group C: [ C]
5. Assign each Code Set Group with a
passcode. For full details of programming the
user passcodes refer to the User Manual.
Key Point Application Example
This application example shows how to use the
“Key Point” circuit to fully set and part-set the
system using a three position keyswitch. The
Keyswitch is mounted in an electrical blanking
plate together with an LED to indicate circuit faults
when setting and part-setting the system.
Zx
Panel output 2
Full Set Part Set
Unset
1K resistor LED
AUX +12V
3 Position keyswitch
e.g., Farnell 140-533
Circuit x
Tx
Figure 29 Key Point Wiring Details
Appendices TS790 & TS900 Installation Manual
56
Page view 59