A printer type C PA6.P (obsolete) or a standard RS232 serial printer via a Menvier Pr inter
Adaptor(MPA/DCI)canbe connected toprovideaprintout of the200 lo g eventsand system
parameters.
An output module type CPA6. OM can be connected to provide an output to a set of
LEDs/relays to indicate circuit activation. Each module will provide up to eight circuit
indications and two modules can be "daisy chained" to provide up to sixteen outputs.
Specific ations
Input Voltage: 240V +/-10% 50Hz
Control Panel: 110mA (normal) 190mA (alar m with extensi on speaker)
Power Suppl y Rating: 1.5 Amp
NETSTAR Remote Keypad: 50mA (normal) 60mA (alarm)
NETLED Remote Keypad: 60mA (normal) 70mA (alarm)
NETARM Arming Keypad: 30mA (normal) 40mA (alarm)
Battery: 12V 7Ah Sealed Lead Acid type
Zones with tampe r loops: 10 - 16
Panel dimension s: 383w x 312h x 95d mm
Panel weigh t (w/o battery): 4.4kg
Remote Key pad dimensions: 150w x 100h x 30d mm
Remote Key pad weight: 280g
Environment: 0 - 55 °C
System Conf iguration
4
Overview TS700 Installation Manual
Printer
Speaker
Aux 12V
Printer
Bell outpu t
Strobe
ou tput
Digi outputs 1- 8
Outputs 1- 4
Remote
Network
TS700
Number of Zones =10 to 16
8 Zones
(DP / EOL)
2 Zones
(DP / EOL)
1 Output
Remote
Keypad
or LEC
2 Zones
(DP / EOL)
1 Output
Remote
Keypad
or LEC
2 Zones
(DP / EOL)
1 Output
Remote
Keypad
or LEC
2 Zones
(DP / EOL)
1 Output
Remote
Keypad
or LEC
Figure 1. TS700 System Configuration