Power-Up Checks
When the initial power-up checks have been
completed, check the following:
1. Switch off the 240V mains supply and measure
the DC voltage at each Node and remote
keypad and ensure the voltage is greater than
11V whilst the system is powered from its
standby battery.
2. Switch on the 240V mains supply and measure
the DC voltage between the mains earth
connection and AUX +12V. Then measure the
DC voltage between the mains earth
connection and AUX 0V. In both cases the
measurement should be 1V or less. If the
voltage is greater than 1V, the system has an
“Earth Fault” and all cables should be checked
for isolation to Earth.
3. Using a voltmeter measure the DC voltage
across the control panel PCB test points (V) and
calculate the system current consumption
(see page 7). Ensure that the reading is not
greater than 1.5A.
4. Repeat test (3) with the system in an alarm
condition and ensure that the reading is not
greater than 1.0A for the TS790 and 1.5A for the
TS900.
The TS790 & TS900 have an overload
protection circuit. If the power supply is
overloaded, the display will show: “PSU
OVERLOAD ! ! !” and sounder will sound.
NVM Defaults
Section Option Default
User Codes User 00 Engineer 1234
User 01 Master 5678
User 02 - 31 Not Used
Panel
Outputs
Panel Output 1 Walk Test
Panel Output 2 Courtesy Light
Panel Output 3 Switch 12V
Panel Output 4 Detector Reset
Panel Output 5 Code Accepted
Panel Output 6 Code Accepted
Panel Output 7 Code Accepted
Panel Output 8 Code Accepted
Digicom
Outputs
Digicom Output 1 Fire
Digicom Output 2 PA
Digicom Output 3 Alarm
Digicom Output 4 Set
Digicom Output 5 Engineer on Site
Digicom Output 6 Bell
Digicom Output 7 Tamper
Digicom Output 8 Second Alarm
Digi
Channels
Digi Channel 1 Fire
Digi Channel 2 PA
Digi Channel 3 Alarm
Digi Channel 4 Set
Digi Channel 5 Engineer on Site
Digi Channel 6 Bell
Digi Channel 7 Tamper
Digi Channel 8 Second Alarm
Node
Outputs
Node Output 1 Walk Test
Node Output 2 Courtesy Light
Node Output 3 Switch 12V
Node Output 4 Detector Reset
Node Output 5 Code Accepted
Node Output 6 Code Accepted
Node Output 7 Code Accepted
Node Output 8 Code Accepted
Node Output 9 Code Accepted
Node Output 10 Code Accepted
Circuits
Circuit 01 Final Exit
Circuit 02 Night (Access)
Circuit 03 - 06 Night
19
TS790 & TS900 Installation Manual System Installation