No/Type Description
041
Time Switch B
This output is controlled by the settings of
“Time Switch B” (see Engineers Menu 3)
042
Time Switch C
This output is controlled by the settings of
“Time Switch C” (see Engineers Menu 3)
043
Access Code
Activates when an “Access” passcode
is entered. The duration of this output is
controlled by the setting of the
“Acc.CODE DUR” timer (see System
Timers).
044
General Fault
Activates during battery fault or when
the system is prevented from being set.
Deactivates when all faults are
cleared.
045
Battery Test
Activates for 1 minute on the hour every
hour. This output is used to test the
battery in remote PSU using a 519FM
monitor PCB).
046
Service Call
Activates when the system is on-line
with a remote PC and Lineload
software.
047
System Full Set
Activates when all areas within the
system are set and deactivates when
any area is unset.
048
Custom O/P A
This output is active when a
combination of output conditions
occur. The combinations are
programmed in Engineers Menu 3 (see
page 47).
049
Custom O/P B
This output is active when a
combination of output conditions
occur. The combinations are
programmed in Engineers Menu 3 (see
page 47).
050
PC output 1
This output can be switched on or off
via the PC and “Lineload” software.
051
PC output 2
This output can be switched on or off
via the PC and “Lineload” software.
052
Sounder Control
Normally used as the 0V connection
for an extension loudspeaker so that
only system alarm tones are
generated. Only suitable for Panel
Outputs 1 and 2.
053
Service Required
Activates when the “SERVICE
REQUIRED” message is displayed and
deactivates when the engineer
passcode is entered.
054
Call Engineer
Activates when the system requires an
“Engineer Reset”, deactivates when
the system is reset by the engineer or
“Remote Reset”.
055
Always Off
Never activates.
056
Duress
Activates when a duress passcode is
entered and deactivates when the
duress alarm is reset.
No/Type Description
057
System Part Set
Activates when the system is part set,
deactivates when the system is fully
unset or fully set.
058
Battery Fault
Activates when a battery fault occurs
and deactivates when the battery fault
is cleared.
059
Set Fail
Activates when any ward fails to set,
deactivates when the set fail condition
is reset.
060
Open/Close
Activates when the system is unset,
deactivates when the system is
set/part-set.
061
ID Alarm
Activates for 2 seconds when any
circuit causes a new alarm condition.
062
Random
Activates randomly (min = 5 minutes,
max =60 minutes)
063
Modem lockout
Activates when the modem is
locked-out (four failed attempts).
Deactivates when a master user
passcode is entered or after 4 hours.
064
Sndr Control A
Activates when “Ward A” is in entry, exit,
alarm or set fail.
065
Sndr Control B
Activates when “Ward B” is in entry, exit,
alarm or set fail.
066
Sndr Control C
Activates when “Ward C” is in entry, exit,
alarm or set fail.
067
Sndr Control S
Activates when “Ward S” is in entry, exit,
alarm or set fail.
068
Chime
Activates for 2 seconds when a circuit
that is programmed as “chime” is
activated.
069
24hr Ccts Omit
Activates when one or more 24 Hour
circuits are omitted.
070
Timed Output
Activates when a “Monitored” circuit is
triggered and remains active for the
duration of the “Monitor Dur" see
System Timers.
071
Abort
Activates for 5 seconds after an alarm
is aborted by the user. The period in
which the alarm may be aborted is set
by the “Abort Delay” see System Timers.
100 - 155
Circuit Mimics
Will mimic (active when circuit is
active) circuits 01 to 56 respectively
200 - 255
Circuit Alarms
Active when a circuit causes an alarm,
for circuits 01 to 56 respectively .
24
Engineer’s Menu 1 TS790 & TS900 Installation Manual