Menvier Security TS900+ Specifications Page 62

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 61
1. If a plug-on digicom is being used program
the digicom channels as shown below, see
“Plug-on Digi Channels”, on page 22. If a
stand-alone digicom is being used program
the digicom outputs as shown below, see
“Digicom/RedCARE Outputs”, on page 22.
Channel No Output Type
3 005 (Alarm)
7 071 (Abort)
8 011 (Second Alarm)
2.
3. Program the “Abort Delay” timer to the required
time (the default is 180 seconds), see “System
Timers”, on page 27.
4. Program the digicom channels so that they
report the required signals.
Text Editing Keys
When programming any text the keys on the
keypad function as shown below:
Cursor Types
[^] This is the normal text editing cursor. Use
the text editing keys as shown above.
[|] This is the number cursor. Use the
numbered keys0-9toenter numeric
data.
Common Key Sequences
Characte
r
Key Sequence
Characte
r
Key Sequence
A1 U5
B1A V5A
C 1AA W 5AA
D 2C X 5AAA
E 2 Y 5AAAA
F 2A Z 5AAAAA
G 2AA : 1CCCCCCC
H 3C ; 1CCCCCC
I 3 < 1CCCCC
J 3A = 1CCCC
K 3AA > 1CCC
L 3AAA ? 1CC
M 4CC @ 1C
N4C ! 0A
O 4 " 0AA
P 4A # 0AAA
Q 4AA $ 0AAAA
R 4AAA % 0AAAAA
S 5CC & 0AAAAAA
T5C
58
Appendices TS790 & TS900 Installation Manual
+12V
+DC POWER
Digicom
(stand-alone)
0V
0V
3-Alarm
Alarm (005) - 3
7-Abort
Abort (071) - 7
8-Confirmation
Second Alarm (011) - 8
TS790/TS900
Figure 29 Alarm Abort & Sequential Confirmation
7 8
0
9
1 2 3
3 5 4
A B C
ENT ESC
AEI
OU0(zero)
Move cursor left Change case Move cursor right
Accept text Space Abandon text editing
Up the alphabet Change cursor Down the alphabet
Figure 1 Text Editing Keys
Page view 61