Section Option Default
Circuits
Circuit 07 Exit Terminator
Circuit 08 PA Audible
Circuit 09 Final Exit
Circuit 10 PA Audible
Circuit 11 - 56 Not Used
System Timers
00 Test Call At 000 seconds
01 No of Re-arms 000
02 Settle Time 007 seconds
03 Part Set Coms Dly 000 seconds
04 Exit Time 030 seconds
05 Entry Time 015 seconds
06 Bell Duration 020 minutes
07 Bell Delay 000 minutes
08 D-Knock Delay 000 seconds
09 Test Time 014 days
10 Second Entry 015 seconds
11 Service Time 000 weeks
12 Payment Time 000 weeks
13 Part Set Bell Delay 030 seconds
14 Courtesy Duration 030 seconds
15 Access Code Dur. 030 seconds
16 Modem Rings 000
17 Point ID Alarm 005
18 Ward Menu Dur. 000 seconds
19 Test Call 000 days
20 2nd Alarm Duration 060 seconds
21 Part Set Codes 021
22 Line Fault Delay 000 minutes
23 Mains Off Delay 000 minutes
24 No. Remote Resets 005
25 Monitor Duration 010 minutes
26 Activity Duration 024 hours
27 Part Set Entry Time 015 seconds
28 Abort Delay 180 seconds
Setting
Modes
Full Set Final Exit Setting
Part Set A Timed Exit
Part Set B Timed Exit
Part Set C Timed Exit
Rem Reset Algorithm 004
Configuration
00 Bell is an SAB Yes
01 User 1 Limited No
Section Option Default
Configuration
02 Fire Signals All No
03 Silent 24hr Circuits No
04 Enable Duress No
05 PA Silent Yes
06 Set With Line Fault Yes
07 User Reset Yes
08 Tamper Eng Reset Yes
09 Hi Security Engineer No
10 O/M's Mimic Ccts Yes
11 Do Battery Test No
12 Final Exit is Night No
13 Audible Time
Switch
No
14 Show P.Set Info. Yes
15 Answer Phone Dft No
16 Set with AC Off Yes
17 Loud Chime Tones No
18 Invert Output 1 No
19 Invert Digi Outputs No
20 On-Line Keypad Yes
21 Restore Point ID Yes
22 User Authorised No
23 Mimic Alarm &
Fault
No
Part Set
Groups
Part Set Group A Ward A
Part Set Group B Ward B
Part Set Group C Ward C
Code Set
Groups
Code Set Group A Ward A
Code Set Group B Ward B
Code Set Group C Ward C
Full Set Group Wards SABC
Custom Text
Reset Message CALL ENGINEER TO
RESET SYSTEM
Banner Message Blank
Location Text Blank
Printer Header Blank
Part Set Banner Blank
Modem
Options
Call Back No 1 Blank
Call Back No 2 Blank
Call Back No 3 Blank
Modem Password Blank
Modem Site No. Blank