Installing a Remote Keypad
Ensurethatthemainsandbatterypowerhasbeen
disconnected and proceed as follows:
1. Connecteach core ofthe 6-core cableto the
interfaceterminals"LEDCBA"(makeanoteof
the colours used for each connection).
2. Passtheyellow flying-lead behind thePCBand
connect it to the [L/S-] terminal.
3. Plug the Interface board into the interface
socket as shown below.
4. Separate the remote keypad cover and base
by using a screwdriver to push two of the clips
(top or bottom) inwards from the cover
retaining slots. Then lift the cover assembly,
noting that the circuit board is connected to
the under side of the cover.
5. Hold the remote keypad base in position
(keyhole to the top) and mark the three
securing holes, drill and plug the wall as
required. Pass the 6-core cable into the base
via the cable entry points as appropriate and
secure the base to the wall.
6. Connecteach core ofthe 6-core cableto the
remotekeypadterminals"LABCDE",ensuring
that the connections through to the control
panel are A to A, B to B, etc. If more remote
keypads are to be fitted, they may be
connected in a star or daisy chain
configuration (providing the cable length to
the last or furthest remote keypad does not
exceed 50 metres).
7. Carefully reattach the front cover assembly to
the remote keypad base ensuring that all
cables are clear of the tamper switch spring
andthecoverissecurelyclippedtothebase.
External Sounder Connections
The following terminals have been provided to
allow connections to an external sounder:
H/O - This is used to provide a permanent -ve
holdofftoexternalsounders,strobesetc.
H/O + This is used to provide a permanent +ve
hold off to external sounders, strobes etc.
Itisprotectedbya1Ampfuse(Bell12V).
TMP - This is the negative tamper return
connection from the external sounder. If
an external sounder is not fitted this input
must be linked to [H/O -].
STB - This is the strobe output which switches to
0Vonalarm.Theoutputisratedat500mA
and should be connected to -ve strobe
trigger input on the external sounder.
TRG - This is the external sounder trigger output
which is rated at 500mA. This output can
be programmed for SAB or SCB
operation, as follows:
SAB: TRG - will switch to 0V on alarm and
will provide a maximum of 500mA.
SCB: TRG - will provide a negative hold
off (500mA), which is removed on alarm.
11
TS400/TS410 Installation Instructions System Installation
InterfacePCB
Flying-lead
connectedtoL/S-
Flying-lead
L/S
Figure 7 Remote Interface Connections
Typical
External Sounder
Control
Panel
H/O +
12V +
H/O -
0V
Tamper In
TMP -
STB -
Tamper Out
TRG -
Strobe +ve
Strobe -ve
Trigger -ve
Figure 8 External Sounder Connections