Extension Loudspeakers
A 16Ohm extension loudspeaker can be
connected between the [L/S-] and [AUX 12V+]
terminals. R37 (located in the top left hand corner
of the PCB) can be cut to reduce the volume of
theinternalsounders(alarmisalwaysfullvolume).
ALM- Terminal
This terminal is switched negative (100mA) on
alarm and is removed when the system is reset. If
theLinkmarked"HOMEALARMINHIBIT"onthemain
PCB is closed, the [ALM-] output is disabled when
the system is part-set (Home). Normally this output
is used to trigger a speech dialler or similar.
RST- Terminal
This terminal may be programmed as:
Detector Reset (DTR RST)
When programmed as Detector Reset the output
may be used for detectors which latch their alarm
condition,andmustbede-poweredtoreset(e.g.,
smoke detectors, vibration detectors etc.). Power
for such detectors must be connected between
[AUX 12V] and [RST-].
Switched 12V (SW12V)
When programmed as Switched 12V the output
may be connected to the latch input terminal on
latching detectors (e.g., PIRs etc.). This feature is
normally used when more than one detector is
connected to a single zone. It allows the user to
identify the alarm source by latching the indicator
LED on the detector that caused the alarm
activation. The latched LED will clear when the
system is reset.
Aux 12V Power
The auxiliary 12V terminals provide a permanent
12V supply for detectors which require a low
voltage supply e.g., PIRs, vibration detectors,
smoke detectors etc. The output is protected by a
1 Amp fuse (Aux 12V).
The maximum available current from the control
panel power supply is 750mA. The following is a
typical example showing how to calculate the
available auxiliary current.
Control Panel = 85mA
External Sounder = 250mA
External Strobe = 115mA
Total = 450mA
Auxiliary Available = 300mA (750 - 450)
SD1(Optional)
The SD1 is a customer programmable speech
dialler which dials pre-programmed numbers to
inform neighbours etc. of the alarm. It is capable
oftransmitting upto3messageslinked toinputsA,
B and C.
12
System Installation TS400/TS410 Installation Instructions
16 Ohm Loudspeaker
L/S -
AUX +12V
Figure 9 Speaker Connections
ALM -
RST -
TRG -
STB-
+
-
TMP -
AUX
TAMPER
L/S -
+
-
ZONE 5 (P A)
H/O
AUX 12V
ZONE 4 (Fire)
TRIG A
TRIG B
0V
+12V
TAMPER
BOX
TRIG C
Set TRIG POLARITY to -ve
Note: Only connect TRIG A (FIRE)
and TRIG B (PA) if zones 4 and 5
areprogrammedasFireandPA.
TS400/TS410SD1
Figure 10 SD1 Connections Details