Exit Time
This timer sets the delay between the user initiating
the setting procedure and the system actually
setting. This only applies when the system is
programmed to set by "Timed Exit", see "System
Options" on page 17.
Toprogramtheexittimeproceedasfollows:
1. Ensure that the engineer’s menu is selected,
then press [4] to select Exit Time.
2. Selecttherequiredexittimebyusingkeys[1] to
[4] to light the appropriate zone LED.Whenthe
LED is lit the exit time will be as shown below:
Zone LED LED On
Zone 1 10 Seconds
Zone 2 30 Seconds
Zone 3 1 Minute
Zone 4 2 Minutes
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer’s menu.
Entry Time
When the entry procedure is initiated, the Entry
Timer is started. If a valid user passcode is not
entered when the timer reaches zero, a full alarm
tone is generated from the internal sounders only
and the timer is restarted. If a valid user passcode
is not entered when the timer reaches zero for the
second time the external sounder is activated.
Toprogramtheentrytimeproceedasfollows:
1. Ensure that the engineer’s menu is selected,
then press [5] to select entry time.
2. Selecttherequiredexittimebyusingkeys[1] to
[4] to light the appropriate zone LED.Whenthe
LEDislittheentrytimewillbeasshownbelow:
Zone LED LED On
Zone 1 10 Seconds
Zone 2 30 Seconds
Zone 3 1 Minute
Zone 4 2 Minutes
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer’s menu.
Bell Duration Time
This timer controls the duration of the external
sounder when the system is triggered into a full
alarm condition.
Toprogramthebelldurationtimeproceedas
follows:
1. Ensure that the engineer’s menu is selected,
thenpress[6] toselectthebelldurationtime.
2. Select the required bell duration time by using
keys [1] to [4] to light the appropriate zone
LED.WhentheLEDislitthebelldurationtimewill
be as shown below:
Zone LED LED On
Zone 1 90 Seconds
Zone 2 3 Minutes
Zone 3 10 Minute
Zone 4 20 Minutes
Zone 5 Continuous
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer’s menu.
Change Engineer’s Passcode
The factory default engineer’s passcode is set to
[1] [2] [3] [4], but the installation engineer should
changethistotheirownpersonal4digitpasscode
as follows:
Tochangetheengineer'spasscodeproceed
as follows:
1. Ensure that the engineer’s menu is selected,
then press [7] to select change engineer’s
passcode.
2. Zone LEDs 1 to 4 will now light.
3. As the new passcode is entered each LED will
go out one by one. When all 4 digits have
been entered, LEDs 1 to 4 will light again and
the new passcode must be re-entered for
confirmation.
4. A high pitched tone indicates the new
passcode was accepted, a low pitched tone
indicates the passcode was not accepted. If
the passcode was not accepted repeat the
procedureagain,usingadifferentpasscode.