Programming
Programming Menus
There are two programming menus within the system. The engineer’s programming menu and the user
programming menu. The figure below shows the structure of both programming menus, however the
engineers programming menu is only covered in full detail within this manual. For full details on the user
options see "User Operating Instructions".
14
Programming TS400/TS410 Installation Instructions
1
2
3 4
5
TAMPERUNSET FINAL EXIT
1
2
34
5
TAMPERUNSET FINAL EXIT
Tamper
LED
Flashes
Unset
LED
Flashes
1 1
1 2 3 4
2 2
3 4
4 6
5 7
6 0
7
8
9
0
AWAY
HOME
HOME
HOME
=ProgramZones =BellTest
Enter the engineer's passcode
(default = )
= View Event Log = Walk Test
= Walk Test = Change Passcode 1
= Exit Time = Change Passcode 2
= Entry Time = Home Set Configuration
= Bell Duration = Return to unset mode
Press twice when the system
is in the unset mode to select
"Chime" zones.
= Engineer's Passcode
= Remote Reset No.
=SystemOptions
= Return to unset mode
= Full set the system
= Part set the system
1
2
3 4
5
TAMPERUNSET FINAL EXIT
1
2
34
5
TAMPERUNSET FINAL EXIT
HOME
5 6 7
Enter first 3 digits of passcode then
(e.g., )
Engineer's Menu User Menu