Menvier Security SD1 Instruction Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Keyswitch Operation
The operation of the keyswitch (zone 3) can be
programmed as either:
AWAY: When keyswitch zone is opened the exit
procedureforAWAYsetwillstartandthesystemwill
attempt to full set. When the zone is closed the
system will unset.
HOME: When the key switch zone is opened the
exit timer will start and when the timer has expired
thesystemwillbepartset.Whenthezoneisclosed
the system will unset.
RST- Output
The operation of the [RST-] output can be
programmed as either:
SW 12V: This can be connected to the "Latch"
input on latching detection devices.
Detector Reset: Thiscanbeusedasthe0V
connection to detectors that require the power to
be removed to reset them (such as smoke
detectors and vibration sensors).
To program the system options proceed as
follows:
1. Ensure that the engineer’s menu is selected,
then press [9] to select system options.
2. Press keys [1] to [6] to toggle the zone LEDs on
or off. The system options will be set according
to the status of the relevant zone LED as shown
below:
Zone LED LED On LED Off
Zone 1 Bell output is an
SAB
Bell output is an
SCB
Zone 2 System is set by
Final Exit
System is set by
Timed exit
Zone 3 System is reset
by the Engineer
System is reset
by the User
Zone 4 System re-arms
three times
System re-arms
once
Zone 5 Keyswitch =
Home set
Keyswitch =
Away set
Final Exit RST output is
SW12V
RST output is
Detector Reset
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard.
Returning to the Unset Mode
Oncealltheengineerprogrammingiscompleted
the system can be returned to the unset mode by
pressing the [0] key. The user passcodes and
"HOME" set configuration must also be
programmed,seethe"UserGuide"forfulldetails.
Full Setting the System (AWAY)
The engineer can use his passcode to full set the
system as follows:
1. Ensure that the engineer’s menu is selected,
then press [AWAY] to full set the system.
2. The exit tone will start and the Final Exit LED will
flash.
3. Whentheexittonestops,thesystemisfullset.
Part-Setting the System (HOME)
The engineer can use his passcode to part set the
system as follows:
1. Ensure that the engineer’s menu is selected,
then press [HOME] to part set the system.
2. The Final Exit LED will flash (HOME set is always
silent and timed).
3. When the high pitched tone is heard the
system is part set.
Unsetting the System
The engineer can only use his passcode to unset
the system when the system is set or part set using
the engineer passcode (i.e., if the system is set by
the user the engineer passcode will NOT unset the
system).
1. Enter via the prescribed entry route.
2. Theentrytone will startandtheFinal Exit LEDwill
flash.
3. Entertheengineer’spasscode(e.g.,1234).
4. The entry tone will stop and the unset LED will
light.
18
Programming TS400/TS410 Installation Instructions
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 24

Comments to this Manuals

No comments